PUMPS & ACCESSORIES
WATER MANAGEMENT
As a responsible system provider, Wilo has the whole water cycle covered with its wide range of pumps, pump accessories and services. Our application expertise extends to (raw) water extraction from wells or water bodies, rainwater utilisation, water purification and water supply. Our portfolio also includes pressure-boosting systems. The portfolio is rounded off with pump solutions for desalination and for sprinkling in professional irrigation/agriculture.
Whether for municipal water management, industry, building services, agriculture or construction and mining, Wilo always works at finding ever more efficient and sustainable solutions for your project.
End suction pump engineered / special
Technical:
Qmax: 3400 m3/hr
Hmax: 220 m
Temperature: up to 120°C
Delivery Size: DN 50 – DN 400
Application:
Water supply / general industry, paper and pulp / building service, fire fighting / irrigation / sprinkler system and treated effluent
Feature:
Mounting: Centreline / vertical, delivery flange orientation change possible and bush bearing
Design:
- End suction top discharge
- Mounting: Horizontal
- Stage: Single
- Back pullout design
- Closed impeller
- Mechanical seal/ gland packing grease/oil lubricated antifriction bearings
Vertical turbine pump
Technical:
Qmax : 50000 m3 /hr max
Hmax: 450 m
Temperature: up to 800 C – higher on request
Delivery Size: DN 100 – DN 2000
Application:
Water supply/ irrigation / cooling water for power plant / flood control / condensate extraction general industry / fire fighting
Feature:
Caission/ cannister construction , tilted pad thrust bearings with cooling arrangement, semi-open impellers, oil / external water lubricated line, shaft bearings, pull out rotating element and instrumentation & controls
Design:
- Vertical wet pit
- Stages: Single / multistage
- Closed impeller
- Above or below floor discharge
- Pumped medium lubricated line
- shaft bearings
- Non pull out bowl/ rotating
- Element antifriction bearings
Standard horizontal split case pump
Technical:
Qmax: m3/hr max 3400
Hmax: 235 m
Temperature: up to 120°C; Higher on request
Delivery Size: DN 50 – DN 400
Application:
Water supply / general industry / building service / fire fighting and spray irrigation / district heating
Feature:
Mounting: Vertical
Design:
- Mounting: Inline horizontal
- Stages : Single/ double, single/ double suction Impellers shaft with sleeves
- Grease lubricated anti-friction bearing
- Mechanical seal/ gland packing
Engineered horizontal split case pump (HSC)
Technical:
Qmax: m3/hr max 18000
Hmax: 270 m
Temperature: up to 120°C; Higher on request
Delivery Size: DN 50 – DN 400
Application:
Water supply/ general industry / ports and docks / fire fighting and irrigation / marine desalination
Feature:
Mounting: Centre line / vertical, drive connection: direct / cardan shaft bush bearing,
Staggered vane design for fan pump application and special suction / delivery orientation* instrumentation and controls
Design:
- Mounting: Inline horizontal
- Stages: One/ two/ three stage single/ double suction impellers
- Grease/ Oil lubricated antifriction bearings
- Mechanical seal/ gland packing
Multistage ring section pump
Technical:
Qmax: 1000 m3/hr
Hmax: 1800m
Temperatur: up to 1600 C
Delivery Size: DN 32 – DN 250
Application:
Mine dewatering / descaling in steel mills / boiler feed application / reverse osmosis for desalination plants water supply / general industry and fire fighting
Feature:
Mounting: Centreline / vertical, multi-outlet design and balance valve design for axial thrust bush bearing / roller bearing
Design:
- Mounting: Horizontal
- Stages: 3 to 15
- Radial flow impellers with vane diffusers mechanical seal/ gland packing
- Grease lubricated antifriction bearings
Norm pump as per EN733
Technical:
Qmax: 600 m3 /hr
Hmax: 150 m
Temperature: up to 1200C
Delivery Size: DN 32 – DN 150
Application:
Building service / sprinkler systems / water supply / general industry
Design:
- End suction top discharge
- Mounting: Horizontal
- Stage: Single
- Back pullout design
- Closed impeller
- Mechanical seal/ gland packing
- Grease lubricated antifriction bearings
End suction pump as per ISO 2858 – MISO / PISO
Technical:
Flow: upto 750 m3/hr
Head: upto 170 m
Temperature: -20ºC to 120ºC
Delivery Size: 32 – 200
Application:
HVAC systems / water transfer / distribution systems / fire fighting / cooling tower
Feature:
Bearing Housing – Unique design for grease & oil lubrication and provisions for temperature gauge / vibration probe. Bearings – NR type replaced with standard type
Design:
- Standards as per ISO 2858
- End suction top discharge
- Stage single
- Back pullout design
- Closed Impeller
- Gland packing/Mechanical seal
Sewage / wastewater pump (Drypit Non Clog)
Technical:
Qmax: 8000 m3/hr
Hmax: 70 m
Temperature: up to 70°C
Delivery Size: DN 50 – DN 800
Application:
Municipal raw sewage transfer / sewage treatment plants / effluent treatment plants / dirty water in industry and sugar mills
Feature:
Mounting: Vertical, delivery flange orientation, change possible and bush bearing
Design:
- End suction top discharge
- End suction top discharge
- Mounting: Horizontal
- Stage: Single
- Casing with hand hole inspection cover mechanical seal/ gland packing large free passage up to 200 mm
- Grease lubricated antifriction bearing